Enables improved fracture healing, as stability is improved when tensile forces are reduced at the fracture site. A tension band wire is a form of orthopaedic internal fixation method used to convert distraction forces into compression forces, promoting bone healing. Olecranon fracture orif with tension band orthobullets. Tension band pin surgical technique continued 3 pin head seating using a mallet, seat the head of the tension band pins into the bone with the tension band pin snapper 800411 included in the kit. The purpose of this study was to investigate whether this remained true or whether there had been a reduction in metalwork removal following improvements in. Choose a wire of sufficient strength to withstand the tensile forces generated in the figureofeight loop 1. Tension bands can enable immediate motion at the involved joint, which allows for an improved functional outcome. In this presentation a tension band internal fixation is used for a transverse fracture of the olecranon. To be able to use a tension band, the opposite cortex. Tension banding is a principle and not a particular implant. Olecranontransverse fracture 21b1 tension band wiring. Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with midpole fractures underwent tension band fixation k wire or cannulated screws with tension band. The principle of tbw is distractive forces at fracture site are converted to compression force. Ao foundation patella fracture tbw tension band youtube.
Nonunion tension band technique technique converts distraction force of triceps into a compressive force. Tension band wiring for complete articular, frontal. The aim of fixation by the implant is the sound union of the fracture. Enables improved fracture healing, as stability is improved. Patella fracture orif with tension band trauma orthobullets. Plate versus tensionband wire fixation for olecranon. As the loop is tightened the bone fragments are compressed together. Olecranon fracture orif with tension band olecranon fracture orif with plate fixation radial head fracture mason type 2 orif tplate and kocher approach radial head fx replacement. Olecranon fractures are a common injury in fractures. Explain the principle of tension band wiring sum up the indications for tension band wiring. Tension band wiring orthopaedicsone articles orthopaedicsone. Tension band wire fixation of olecranon fractures youtube. Ao foundation tension band wiring tbw shirish karki. Biomechanical evaluation of current patella fracture fixation techniques.
Tension band wiring of olecranon fractures with nonsliding pins report of 20 cases eilif larsen and claus munk jensen twenty consecutive patients with displaced fractures uneventful in 19 patients after a median of 6 weeks. Efficacy and safety of tension band wiring versus plate. Fractures of the kneecap and the olecranon process of the elbow are commonly treated by this method. Tension band principle is utilized in the application of plate fixation and tension band wiring. Interfragmentary compression and direct bone healing is obtained. Multifragmentary fractures cannot be fixed with a tension band. The aim of this study was to compare the superiority between the newly designed modified ao tension band wiring technique and the traditional modified ao tension band wiring technique in treating an olecranon fracture. Thread tension band wire in figure of 8 around k wires screw and under triceps aponeurosis posteriorly. Tension band wire tbw fixation is commonly employed for simple isolated stable displaced fractures of the olecranon type iia according to. This is mostly due to protrusion of the proximal ends of the kwires or by the twisted knots of the metal wire tension band. In contrast, plate fixation is thought to provide superior outcomes for unstable comminuted olecranon fractures.
Biomechanical comparison for different configurations of. Tension band wiring is an optimal mechanical principle for early functional motion. Alternatively, suture fixation may be helpful for inferior pole patellar fractures, especially with comminution andor osteoporosis. The tension band suture technique was originally described by bindra 6 in 1996. The tension band technique for olecranon fractures yields good clinical outcomes. Plate versus tension band wire fixation for olecranon fractures a prospective randomized trial andrew d. Modified tension band using fiberwire sutures showed satisfactory clinical results, with a low incidence of complications and reoperations. Plate versus tension band wire fixation for olecranon fractures duration. Principle of tension band wiring n its application slideshare. Tension band wire tbw fixation is commonly employed for simple isolated stable displaced fractures of the olecranon type iia according to the mayo classification 35. The biomechanical theory behind the fixation is explained with experimental data. Tensionband wiring for proximal, collateral ligament avulsion.
Tension band wiring tbw which was introduced by weber and vasey7 remains the most widespread method for fracture fixation in isolated olecranon fractures. Is tension band wiring technique the gold standard for. Depending on fracture stability motion will increase the interfragmentary compression. Tension band wiring may be used in combination with cerclage wiring andor lag screws. Tension band wiring ao surgery reference 271012 12. The purpose of this study was to investigate whether this remained true or whether there had been a reduction in metalwork removal following improvements in surgical technique. To apply an implant with a tension band technique, a device is fixed eccentrically to the convex side of the fractured bone. This technique was modified by h patankar 9 by the use of kirschner wire k wire or an additional midline. In many patients, implants irritate overlying soft tissues and cause pain. However, the standard technique, which involves using two kirschner wires through the patella, can cause problems with prominent hardware, and difficulty capturing the change to figure of eight wire. Olecranon tension band wiring cambridge orthopaedics.
Tension band principle and its applications bone and spine. Repair of olecranon fractures using fiberwire without. Choose a wire of sufficient strength to withstand the tensile forces generated in. This enables improved fracture healing, as stability is. The contraction of the triceps avulses the olecranon and tears the distal triceps expansion. Modified tension band wiring is the best treatment for displaced transverse fractures. Tension band wiring tbw remains the most common operative technique for the internal fixation of olecranon fractures despite the potential occurrence of subjective complaints due to subcutaneous position of the hardware. The literature and surgeons describe tbw as an uncomplicated, always available and convenient operation producing excellent results.
The eligible studies were acquired from pubmed, cnki, embase, cochrane. The tension band converts tensile forces into compression forces. Tension band wiring is a fixation technique which results in absolute stability. Patella fracture orif with tension band orthobullets. Penetrating injuries affecting the articular surface e.
His radiographs show a comminuted displaced olecranon fracture involving 25% of the articular surface with global osteopenia. Tension band wiring of this fracture has been shown to be effective and usually provides good results. Radiocarpal fracture dislocation trauma orthobullets. In order to be able to use a tension band, the anterior far cortex cannot be comminuted and must provide a buttress to allow compression. He has pain and swelling at the elbow without evidence of instability. Ao tensionband osteosynthesis of displaced olecranon. Fiberwire tension bands could be used in place of metal wire tension bands to treat patellar fracture, reducing the rate of symptomatic hardware. Tensionband wiring for proximal articular, avulsion. Tension band wiring is a technique in which the bone fragments are transfixed by kwires which are then also used as an anchor for a loop of flexible wire. The use of tension band wire technique for patella fractures fixation is a wellestablished technique.
Tensionband wiring of olecranon fractures with nonsliding. The presence of comminution is a contraindication for tension band treatment. In a case such as the illustrated fracture, the tension band will be applied in static mode. Orthobullets technique guides cover information that is not testable on abos part i. Tension band wire is often applied in a figure of 8 fashion around. Orthobullets techniques are largerly incomplete at this time, and will see rapid improvement as they are updated by experts in the field over the coming months. The tension band wiring tbw technique is a common treatment for the fixation of olecranon fractures with up to three fragments. Modified tension band technique for patella fractures. Tension band wiring of olecranon fractures davies 2009.
Introduction the tension band technique converts a tensile force into a compressive force. Modified anterior tension band wiring two lag screws cannulated screws and tension band cannulated lag screw with tension band wiring stronger than routine anterior tension band less articular surface displacement with lag screws carpenter je, et al. Loss of reduction 22% increased in osteoporotic bone. Open reduction and internal fixation with tension band wiring. In the suture cohort, one fracture failed open repair 7. The acumed tension band pin system is an interlocking solution designed to provide lowprofile, secure fixation for patella, olecranon, and malleolar fractures without k wire irritation or postoperative pin migration. Olecranon transverse fracture tbw tension band wir youtube. The olecranon is forced into the distal humerus by hyperextending the elbow on an outstretched hand. Wire migration and elbow pain related to the use of the kwires in this technique reduce the optimal results that can be achieved in the treatment of this type of fractures. Functional outcome with modified tension band wiring.
However, the standard technique, which involves using two kirschner wires through the patella. The aim of the current study is to discuss whether tbw or pf technique of internal fixation is better in the treatment of ofs, using the method of metaanalysis. This innovative solution can reduce postsurgical complications associated with traditional tension band pinning with kwires. Does kwire position in tension band wiring of olecranon. Tension band wiring tbw is the goal standard for simple non comminuted olecranon fractures. Olecranon fracture orif with tension band trauma orthobullets. Thakur, 2nd edition, ch7 a wire, a cable or a nonabsorbable suture is used to perform the function of a tension band.
1325 916 421 1638 1464 852 543 328 1000 590 1417 938 511 1566 613 1581 505 384 602 822 39 1530 84 29 152 964 1392 69 364 1053 659 776 1404 1152 1011 1498 784 1470 1204 616 1479 370